Honeywell MCXL-XWHM-Y-3C 4-Gas Detector
Honeywell MCXL-XWHM-Y-3C 4-Gas Detector


Buy Honeywell MCXL-XWHM-Y-3C BW MicroClip XL detector for LEL, O2, H2S and CO. Request price, availability and delivery from HKXY.
Get MCXL-XWHM-Y-3C Price
Honeywell BW MCXL-XWHM-Y-3C MicroClip XL
Honeywell MCXL-XWHM-Y-3C 4-Gas Detector Available from HKXY
Get MCXL-XWHM-Y-3C Price
Honeywell BW MCXL-XWHM-Y-3C MicroClip XL
Honeywell MCXL-XWHM-Y-3C 4-Gas Detector Available from HKXY
HKXY is now accepting quotation requests for the Honeywell BW MCXL-XWHM-Y-3C MicroClip XL portable multi-gas detector.
Designed for personal gas monitoring, this compact detector simultaneously measures combustible gases, oxygen, hydrogen sulfide and carbon monoxide. It is suitable for workers operating in confined spaces and industrial locations where multiple gas hazards may be present.
Customers can contact HKXY for the latest MCXL-XWHM-Y-3C price, availability, technical information and international shipping options.
What Is the Honeywell MCXL-XWHM-Y-3C?
The MCXL-XWHM-Y-3C belongs to the Honeywell BW MicroClip XL series of portable multi-gas detectors.
It continuously monitors four common workplace gas hazards:
• Combustible gases: 0–100% LEL
• Oxygen (O2): 0–30.0% volume
• Hydrogen sulfide (H2S): 0–100 ppm
• Carbon monoxide (CO): 0–500 ppm
The detector displays real-time gas concentrations on its LCD and warns the wearer through audible, visual and vibrating alarms when configured alarm thresholds are reached.
MCXL-XWHM-Y-3C Specifications
• Brand: Honeywell BW
• Series: MicroClip XL
• Part number: MCXL-XWHM-Y-3C
• Product type: Portable four-gas detector
• Detection method: Diffusion
• Gases detected: LEL, O2, H2S and CO
• Combustible gas range: 0–100% LEL
• Oxygen range: 0–30.0% volume
• Hydrogen sulfide range: 0–100 ppm
• Carbon monoxide range: 0–500 ppm
• Alarm types: Audible, visual and vibrating
• Audible alarm level: Approximately 95 dB
• Operating temperature: -20°C to +50°C
• Operating humidity: 0–95% RH, non-condensing
• Typical battery runtime: Up to 18 hours under normal conditions
• Battery type: Rechargeable lithium-polymer
• Dimensions: Approximately 11.3 × 6.0 × 3.2 cm
• Weight: Approximately 190 g
• User interface: One-button operation
• Protection rating: IP68 for current MicroClip XL series specifications
Specifications should be confirmed against the product label, supplied documentation and applicable regional certification before purchase or use.
Four-Gas Protection in One Compact Detector
Industrial personnel may encounter more than one atmospheric hazard at the same worksite.
Oxygen deficiency can occur in enclosed areas. Carbon monoxide and hydrogen sulfide may be present during industrial operations, while combustible gases can create a fire or explosion risk.
The MCXL-XWHM-Y-3C allows personnel to monitor all four hazards with one wearable detector, reducing the need to carry multiple single-gas instruments.
LEL Monitoring
The combustible gas channel measures gas concentration as a percentage of the Lower Explosive Limit. This helps warn users when combustible gas levels are approaching a potentially dangerous concentration.
Oxygen Monitoring
The oxygen sensor helps identify oxygen-deficient and oxygen-enriched atmospheres. Both conditions may create serious safety risks.
Hydrogen Sulfide Monitoring
Hydrogen sulfide is a highly toxic gas that may occur in wastewater facilities, oil and gas operations, sewers and other industrial environments.
Carbon Monoxide Monitoring
Carbon monoxide is colorless and odorless. Personal monitoring is important wherever combustion processes, engines or other CO sources may be present.
Typical Applications
The Honeywell BW MicroClip XL is commonly selected for:
• Confined-space entry
• Oil and gas operations
• Refinery maintenance
• Petrochemical facilities
• Wastewater treatment
• Utility tunnels
• Tank inspection
• Industrial maintenance
• Fire and emergency response
• Construction and infrastructure work
• Manufacturing facilities
The instrument should be selected and used according to the worksite risk assessment and applicable safety procedures.
Designed for Everyday Personal Monitoring
Compact and Lightweight
At approximately 190 grams, the detector can be clipped to a worker’s clothing without adding excessive weight.
One-Button Operation
The simplified control interface helps make routine operation easier while reducing unnecessary menu navigation.
Real-Time LCD Readings
Gas concentrations are displayed continuously, allowing personnel to check current atmospheric conditions directly on the instrument.
Multiple Alarm Methods
Audible, visual and vibrating alarms help notify the wearer in noisy, dark or high-activity environments.
IntelliFlash Status Indication
The flashing green IntelliFlash indicator provides an at-a-glance visual indication of detector status according to the device configuration.
Rechargeable Battery
The MicroClip XL uses a rechargeable lithium-polymer battery and is designed to support a full work shift under specified operating conditions.
Rugged Environmental Protection
The MicroClip XL series is designed for challenging industrial work environments and carries an IP68 protection rating under current Honeywell series specifications.
Is MCXL-XWHM-Y-3C the Correct Version?
Honeywell BW MicroClip part numbers can include suffixes identifying gas configuration, housing color and regional version.
For MCXL-XWHM-Y-3C:
• MCXL identifies the MicroClip XL series
• XWHM identifies the four-gas configuration
• Y identifies the yellow housing
• 3C is associated with a regional market version
Regional versions may differ in labeling, supplied instructions or certification markings. Before ordering, customers should confirm that the product certification and language requirements are suitable for the country where the detector will be used.
For replacement orders, send HKXY a clear photo of the existing detector label. This helps verify the complete part number and regional version.
Important Questions Before Buying
Before requesting a quotation, confirm the following:
1. Which gases need to be monitored?
The MCXL-XWHM-Y-3C configuration monitors LEL, O2, H2S and CO.
2. Which certification is required?
Hazardous-location and regional certification requirements depend on the installation country and end-use application.
3. How many detectors are required?
HKXY accepts inquiries for individual replacement units and project quantities.
4. Are calibration accessories needed?
Portable gas detectors require regular bump testing and calibration. State whether compatible calibration gas, regulators, tubing, chargers or docking equipment are also required.
5. When is delivery required?
Providing the delivery destination and required date allows HKXY to prepare a more accurate quotation.
Request an MCXL-XWHM-Y-3C Quote
To receive a quotation, submit the following information through the HKXY website:
• Part number: MCXL-XWHM-Y-3C
• Required quantity
• Delivery country and postal code
• Required certification
• Required delivery date
• Accessories required, if any
• Existing detector label photo, if replacing a unit
HKXY can respond with:
• Current availability
• Commercial quotation
• Estimated lead time
• Shipping options
• Available technical documents
• Part-number verification support
• Information about compatible accessories
[GET MCXL-XWHM-Y-3C PRICE]
Contact HKXY today for Honeywell BW MCXL-XWHM-Y-3C pricing, availability and worldwide supply information.
Important Safety Notice
A portable gas detector is a safety-critical instrument. It does not replace workplace risk assessment, ventilation, entry procedures or emergency planning.
The detector must be bump tested, calibrated, charged, inspected and maintained by trained personnel according to current Honeywell instructions and applicable regulations. Alarm settings and certification must be verified before use.
HKXY is an independent supplier. Honeywell, BW and MicroClip are trademarks of their respective owner. Unless expressly stated otherwise, references to these names do not imply authorization, affiliation or endorsement.